LOD 400 shop drawings, approved and installed as drawn.
We model every element with its true size, position, supports and access zones, and produce coordinated shop drawings for every discipline, matched to the developer's and consultant's requirements: templates, naming and submittal procedure.

Every sheet the site needs.
- Combined services drawingsAll MEP systems on one coordinated sheet, with levels and clearances.
- Discipline shop drawingsHVAC, plumbing and drainage, fire protection, electrical and ELV.
- Architectural and structuralWalls, ceilings, finishes and openings; structural details and connections.
- Roads, infrastructure and landscapeRoad, composite utility, crossing-section and landscape shop drawings.
- Builder's work drawingsOpenings, sleeves and penetrations through structure and walls, coordinated and dimensioned.
- Sections and detailsEvery congested zone cut and dimensioned for the installer.
- Fabrication drawingsPipe and duct spools and multi-service racks, ready for the workshop.
- Schedules and quantitiesEquipment, materials and quantities straight from the model.
- Submittal registerEvery sheet tracked from first issue to approval.
- RVT
- NWD / NWC
- IFC
- DWG
- BCF
The difference between a drawing you read and a drawing you install.
Per the BIMForum LOD Specification: LOD 300 defines the element's size and location; LOD 400 adds what is needed to fabricate and install it. Owners' requirements typically ask for LOD 350 at the end of design, LOD 400 in construction and a verified LOD 500 as-built.
| System | LOD 300 | LOD 400 |
|---|---|---|
| Ductwork | Main routes and sizes | Exact routes with every fitting, hangers and supports, insulation and access panels |
| Piping | Mains and diameters | Every fitting and valve, slopes, supports and sleeves |
| Fire protection | Mains and head layout | Branches coordinated with the ceiling grid, hangers and final head positions |
| Electrical and ELV | Main containment routes | Tray, trunking and conduit with supports, bends and segregation |
| Structure | Members and sizes | Connections, openings and embeds |
| Architecture | Walls and openings | Set-out, interfaces, ceiling grids and access openings |
In the developer's template and naming, from the first sheet.
Title blocks and sheet numbering, model and layer naming, shared parameters, system colour coding, suitability and review codes all follow the owner's requirements (EIR, MDS) and its CDE protocols, whoever the developer is.
- Three checks before any sheet leaves us: an automated model check, a discipline engineer review and a coordination review.
- Every comment is logged on the owner's comment sheet, fixed in the model rather than just the sheet, and the sheet re-issued under the right review code.
- A weekly report on the status of every sheet and every open comment.

Handover & operation
As-built models and asset data, ready for operation and maintenance.
Before you ask.
Not here? Send us your question and we will reply the same working day.
What is the difference between LOD 350 and LOD 400?
LOD 350 adds the interfaces between systems, such as supports and connection points, enough for coordination. LOD 400 adds fabrication, assembly and installation detail, so the drawing is ready for the workshop and the site.
What about LOD 500?
In the market, LOD 500 usually means a field-verified as-built model. The BIMForum specification does not define it as a level of development, so we agree with the developer up front what it means on their project: what is measured on site, to what accuracy, and which data is required.
Do you work in our template and title block?
Always. We set up the developer's or contractor's templates before production starts and use them on every sheet.
How do you handle consultant comments?
Every comment is logged against its sheet and fixed in the model, not just on the sheet, then the sheet is re-issued with a written response. We send the list of open comments every week.
Send the scope. Get a clear proposal.